NO PASSWORD. FULL CONTROL.
A hacker can take control of a smart home device without even knowing the device owner's password. Of the three vulnerabilities discovered in the Philips Hue Bridge Pro, two could allow an attacker to bypass authentication and execute code with root privileges. This threat is related to the smart lighting controller itself, not the bulbs, and requires full network access to the device. The control port must also be reachable from the attacker's network.
The CVE-2026-118632 vulnerability is in the HTTP service. This service, which by default accepts HTTPS connections on port 443, does not sufficiently validate the string before including it in an SQL query. This vulnerability allows a hacker to execute arbitrary code as root, thereby gaining maximum privileges in the system. Researchers from the Zero Day Initiative assigned this vulnerability a CVSS score of 8.0. SQL injection typically requires authorized user privileges. But the problem is that a separate vulnerability, CVE-2026-122044, allows for bypassing login verification without credentials. This issue also affects a service on port 443 and is related to a malfunctioning security mechanism. Another identified vulnerability, CVE-2026-118631, affects the factory data service component on port 5001. In this case, an argument handling error allows modification of files with the service account's permissions. However, to initiate an attack via this path, one must first run code with limited privileges within the device container. The research does not describe a separate method for gaining root access with this vulnerability. It should be noted that all three of these issues have already been fixed in Hue Bridge Pro firmware 6.1.2071524030. This firmware was released several weeks before the public disclosure of the identified vulnerabilities. However, when the new firmware was released, the fixes were not described separately. The manufacturer recently released an even newer version, 6.3.2071556020. Philips Hue representatives now recommend enabling automatic updates in the app. This is necessary to ensure the device receives patches without manual installation. This isn't the first time a serious issue has been identified with the Bridge Pro system. Back in the summer, vulnerability CVE-2026-73669 was disclosed in the Mosquitto MQTT broker. This bug allows connection to the system without entering a password. An unauthorized attacker could then read device data and control lighting. This bug was also fixed in an updated version. A couple of weeks ago, at the Pwn2Own Ireland 2026 tournament, one team demonstrated a convincing hack of Bridge Pro using seven vulnerabilities. And those hacks, which included the three newly discovered CVEs, have not been identified. The developers of these systems have a lot of work to do to identify and fix all the bugs. For now, controllers with older firmware and accessible vulnerable services remain at risk.